About us
NVMERIA brings together TECSA’s expertise in numerical simulation, computational engineering and risk analysis applied to safety.
Our work
NVMERIA develops numerical models of the phenomena on which the safety of plants, buildings and infrastructure depends: releases of hazardous substances, fires and explosions, structural behaviour under exceptional actions, egress and crowd dynamics, reliability of protection systems.
The model is the tool. What is delivered is a technical report that answers a precise question, states its assumptions, quantifies its uncertainty and sets out the conditions within which its results remain valid.
Where we step in
Simulation is most useful in three situations: when the prescriptive route leads to disproportionate or impractical solutions and a performance-based demonstration is needed; when no applicable simplified model exists for the phenomenon; when a result will have to be upheld before a regulator or in court.
NVMERIA works both on direct appointment and in support of other designers. Its work also includes independent review of models developed by third parties.
Three working principles
Geometry and physics are chosen together
The space decides what matters: ventilation in an enclosed room, the obstacles that accelerate the flame among the pipes of a plant, the wind in the open. Each case therefore calls for different choices of turbulence, combustion and computational grid, and the geometry gets the same care as the physics.
Every value with its range
Each design value is reported with the range it may vary within and with its sensitivity to the parameters that govern it: geometry, boundary conditions, source term, modelling choices.
Every outcome goes into the report
Computation is not there to confirm a position decided in advance: it may support it or contradict it. Either way the result goes into the report, because a document that reports only favourable outcomes does not stand up to review.
The people
NVMERIA’s results depend on the experience of the people who produce them. These are the engineers who set up, run and check the models.
Prof. Luca Fiorentini
Owner and Director, TECSAHe works on risk analysis and RAM analysis, fire risk assessment, fire safety engineering and forensic engineering of industrial accidents and complex events. He is the author of four internationally recognised books on these subjects, published by Wiley. He teaches and carries out research at university level. He sits on numerous international standards and research committees (NFPA, SFPE) and on the editorial boards of several scientific journals.
- Fiorentini L., Sicari R., Cancelliere P. (2026). ALARP: Demonstrating and Documenting Risk Reduction Across Engineering Sectors. Wiley, in press
- Fiorentini L., Dattilo F. (2023). Fire Risk Management: Principles and Strategies for Buildings and Industrial Assets. Wiley · doi:10.1002/9781119827467
- Fiorentini L. (2021). Bow-Tie Industrial Risk Management Across Sectors: A Barrier-Based Approach. Wiley · doi:10.1002/9781119523857
- Fiorentini L., Sicari R. (2020). Analisi, valutazione e gestione operativa del rischio. Bow-Tie, Root Cause Analysis ed altri strumenti conformi alla ISO 31000 per la gestione sistemica del rischio nelle organizzazioni. EPC Editore
- Fiorentini L., Marmo L. (2018). Principles of Forensic Engineering Applied to Industrial Accidents. Wiley · doi:10.1002/9781118962800
- Fiorentini L., Marmo L. (2011). La valutazione dei rischi di incendio. EPC Editore
Cristian Giovanniello
Fluid dynamics · Fire and explosionsHe works on fluid dynamics modelling for safety applications, focusing on fires and explosions, which he simulates with FDS, Viper and Ansys Fluent. He applies the same tools to CFD studies of industrial stacks and the dispersion of their emissions. He also handles tunnel ventilation using one-dimensional tools such as IDA Tunnel. Alongside modelling, he carries out risk analysis, fire prevention, hydraulic calculations, and RAM and human reliability analysis. He is a PhD candidate at the Politecnico di Milano, researching CFD methods for safety applications.
- PhD in progress at the Politecnico di Milano: CFD methods for safety
- Giovanniello C., Fiorentini L., Respighi A., Busini V. (2026). Consequence Assessment of Detonations in Explosive Material Handling Facilities: An Integrated Approach. Chemical Engineering Transactions 126, 169–174 · doi:10.3303/CET26126029
- 5th Summer School on Fire Dynamics Modeling (2026)
Andrea Respighi
Fire engineer · Fire modellingHe specializes in numerical fire simulation for civil, industrial and wildland scenarios (OZONE, CFAST, FDS, PANFIRE, FlamMap, WindNinja). He develops scripts to automate result analysis and couple models, such as SAFIR with FDS, and also designs active fire protection systems.
- Exida Fire & Gas Professional (FGP) certification
- Giovanniello C., Fiorentini L., Respighi A., Busini V. (2026). Consequence Assessment of Detonations in Explosive Material Handling Facilities: An Integrated Approach. Chemical Engineering Transactions 126, 169–174 · doi:10.3303/CET26126029
- Fiorentini L., Lappano M., Berteletti N., Respighi A., Sicari R., Scarpellini S.M., Breveglieri F. (2018). Case study, building specifications: High-rise health care facility – Italian approach. SFPE 12th International Conference on Performance-Based Codes and Fire Safety Design Methods, Honolulu
Rosario Sicari, PE
Risk analysis and structuresA licensed engineer, with TECSA since 2017. He specializes in finite element (FEM) numerical modelling of civil and industrial structures, focusing on seismic vulnerability and on fire resistance with the SAFIR code, also coupled with CFD simulations for non-linear thermo-structural analysis. An expert in risk management (ISO 31000), bow-tie analysis and Barrier Failure Analysis (BFA), he applies human reliability analysis (HRA) methods such as SPAR-H and SHERPA and supports forensic engineering investigations of incidents, near misses and non-conformities.
- Fiorentini L., Sicari R., Cancelliere P. (2026). ALARP: Demonstrating and Documenting Risk Reduction Across Engineering Sectors. Wiley, in press
- Fiorentini L., Sicari R. (2020). Analisi, valutazione e gestione operativa del rischio. Bow-Tie, Root Cause Analysis ed altri strumenti conformi alla ISO 31000 per la gestione sistemica del rischio nelle organizzazioni. EPC Editore
- Fiorentini L., Lappano M., Berteletti N., Respighi A., Sicari R., Scarpellini S.M., Breveglieri F. (2018). Case study, building specifications: High-rise health care facility – Italian approach. SFPE 12th International Conference on Performance-Based Codes and Fire Safety Design Methods, Honolulu
- Chiaia B., Marmo L., Fiorentini L., Sicari R., Cantelli Forti A., Bigi S. (2017). Incendio della motonave Norman Atlantic: indagini multidisciplinari in incidente probatorio. IF CRASC ’17, Dario Flaccovio Editore, Milano, 129–140
- SAFIR® course (first Italian edition)
Nicolò Berteletti
Senior fire engineer · NFPA CFPSA fire safety expert registered with the Italian Board of Fire Protection Professionals (ex L. 818) and NFPA CFPS certified, he works on fire prevention and on the design of Fire & Gas detection systems and active and passive fire protection systems, including smoke and heat exhaust and hydraulic modelling of fire protection networks. He carries out audits and inspections at railway infrastructures and chemical and petrochemical plants and performs fire risk assessments according to the Italian Fire Prevention Code (Ministerial Decree of 3 August 2015). He also carries out forensic fire investigations and reconstructions according to NFPA 921 and wildfire simulations with FlamMap/FARSITE and WindNinja, including satellite imagery analysis with European Space Agency (ESA) tools.
- Certified Fire Protection Specialist (NFPA)
- CINEAS master in “Fire Investigations” (2024)
- Vazzana F., Fiorentini L., Dattilo F., Berteletti N. (2024). Risk Management in Energy Storage using Lithium-Ion Batteries: Emerging Risks Associated with BESS Systems. Chemical Engineering Transactions 111, 463–468
- Fiorentini L., Berteletti N., Dattilo F., Vazzana F. (2023). La gestione del rischio nello stoccaggio energetico mediante batterie agli ioni di litio: i rischi emergenti connessi con gli impianti BESS. SAFAP 2023 proceedings, Brescia
- Fiorentini L., Lappano M., Berteletti N., Respighi A., Sicari R., Scarpellini S.M., Breveglieri F. (2018). Case study, building specifications: High-rise health care facility – Italian approach. SFPE 12th International Conference on Performance-Based Codes and Fire Safety Design Methods, Honolulu
- Zio E., Di Maio F., Berteletti N., Carpignano A., Ganci F. (2008). Analisi delle incertezze nella modellazione di un impianto di distribuzione di idrogeno per autotrazione. Convegno VGR 2008, Pisa
Publications
A selection of papers and books by the group in the fields NVMERIA works in.
- 2026Fiorentini L., Sicari R., Cancelliere P. ALARP: Demonstrating and Documenting Risk Reduction Across Engineering Sectors. Wiley, in pressRISK
- 2026Giovanniello C., Fiorentini L., Respighi A., Busini V. Consequence Assessment of Detonations in Explosive Material Handling Facilities: An Integrated Approach. Chemical Engineering Transactions 126, 169–174 · doi:10.3303/CET26126029EXPLRISK
- 2024Vazzana F., Fiorentini L., Dattilo F., Berteletti N. Risk Management in Energy Storage using Lithium-Ion Batteries: Emerging Risks Associated with BESS Systems. Chemical Engineering Transactions 111, 463–468BESSRISK
- 2024Fiorentini L., Cancelliere P. Fire Protection Systems functional safety requirements in performance-based design: proposed workflow and a simple case application. Journal of Physics: Conference Series 2885, 012088 · doi:10.1088/1742-6596/2885/1/012088FIRE
- 2023Fiorentini L., Dattilo F. Fire Risk Management: Principles and Strategies for Buildings and Industrial Assets. Wiley · doi:10.1002/9781119827467FIRERISK
- 2021Danzi E., Fiorentini L., Marmo L. FLAME: A Parametric Fire Risk Assessment Method Supporting Performance Based Approaches. Fire Technology 57, 721–765 · doi:10.1007/s10694-020-01014-9FIRERISK
- 2021Danzi E., Fiorentini L., Marmo L. Fire & Explosion Risk Assessment: Application to the Fine Chemicals Industry. Chemical Engineering Transactions 86, 241–246FIREEXPL
- 2021Fiorentini L. Bow-Tie Industrial Risk Management Across Sectors: A Barrier-Based Approach. Wiley · doi:10.1002/9781119523857RISK
- 2020Fiorentini L., Sicari R. Analisi, valutazione e gestione operativa del rischio. Bow-Tie, Root Cause Analysis ed altri strumenti conformi alla ISO 31000 per la gestione sistemica del rischio nelle organizzazioni. EPC EditoreRISK
- 2019De Biagi V., Chiaia B., Fiorentini L., Zannini Quirini C. Seismic Vulnerability Assessment of Fuel Storage Tanks in Italy. Journal of Pressure Vessel Technology 141(1), 010905 · doi:10.1115/1.4040313STRUCT
- 2018Fiorentini L., Marmo L. Principles of Forensic Engineering Applied to Industrial Accidents. Wiley · doi:10.1002/9781118962800FORENSIC
- 2016Fiorentini L., Marmo L., Danzi E., Puccia V. Fire risk assessment of photovoltaic plants. A case study moving from two large fires. Chemical Engineering Transactions 48, 427–432FIREFORENSIC
- 2014Fiorentini L., Marmo L., Piccinini N. Forensic engineering applied to the analysis of a gas explosion in a residential building. International Journal of Forensic Engineering 2(2), 152–164 · doi:10.1504/ijfe.2014.066317EXPLFORENSIC
- 2013Marmo L., Piccinini N., Fiorentini L. Missing safety measures led to the jet fire and seven deaths at a steel plant in Turin. Dynamics and lessons learned. Journal of Loss Prevention in the Process Industries 26(1), 215–224 · doi:10.1016/j.jlp.2012.11.003FIREFORENSIC
- 2011Fiorentini L., Marmo L. La valutazione dei rischi di incendio. EPCFIRE
- 2009Crippa C., Fiorentini L., Rossini V., Stefanelli R., Tafaro S., Marchi M. Fire risk management system for safe operation of large atmospheric storage tanks. Journal of Loss Prevention in the Process Industries 22(5), 574–581FIRERISK
The group
NVMERIA is a division of TECSA. It works on direct appointments and within the group’s assignments, where the question has already been framed in regulatory, engineering or judicial terms.
TECSA S.r.l.
TECSA works in process safety, fire prevention, machinery safety, occupational hygiene, project risk management and environmental matters. It provides technical consulting, risk assessments, compliance documentation and specialist training to industrial and institutional clients. Many of the questions NVMERIA works on come from these assignments.
Visit the site · tecsasrl.itMFC Forensic
MFC Forensic is the TECSA division dedicated to the technical investigation of incidents: reconstruction of the causes of fires, explosions and accidents, analysis of physical evidence, support to the parties and to the judicial authority. It is the division NVMERIA works with most often: computation checks whether the reconstruction of an event is physically consistent.
Visit the site · mfcforensic.itIn joint assignments the roles are clear. TECSA and MFC Forensic define what has to be demonstrated: the regulatory framework, the acceptance criteria, the credible accident hypotheses, the expert’s question. NVMERIA checks by computation whether those hypotheses hold, and with what margin.